You can now turn off the authentication to enable you to use more simple one line HTTP commands like you can with Vera Luup Requests. Scene example with authentication turned on: If you wish to leave authentication turned on you will need to use this Python script here to get your token from your Ezlo hub / Ezlo cloud.

3739

2010-04-13

In this example, chime "9" will play through node 32. Examples. Google --> MIOS code repository Luup Somfy Walkthrough; Luup plugins and Luup code; Vera uses JSON as the native format, so any calls to Vera should request JSON in preference to XML. It's quicker. Communicating with your plugin. UI Notes has a good summary on communicating with Vera and/or Vera plugins local status, result = luup.inet.wget("http://192.168.0.28:8080/json.htm?type=command&dparam=switchlight&idx=433&switchcmd=On", 5) Click on "Save" In Domoticz, it is better to make the switch as "protected" in its options. Switch Master Domoticz and Slave on Vera.

  1. Livplagg
  2. Electronic library free
  3. Pensionsmyndigheten hållbara fonder
  4. Brio leksaker osby
  5. World trade center helsingborg
  6. I hardly knew ye
  7. Konsumentprisindex med 1980 som basår

Refer to Luup_IR also. LUUP Code. In this step you can add custom LUUP code to your Scene. You can use this to make a scene conditional – "do something only if some condition is met" – or to do very advanced operations. This is strictly for Advanced Users only and we won’t be covering that on this guide. For an overview of the LUUP potential see the Luup Scenes Here is the LUUP code used in my example: local dID = 145 – Device ID of virtual switch to activate / deactivate VMC automation local allow = true – true runs scene during period, false blocks it local status = luup.variable_get(“urn:upnp-org:serviceId:VSwitch1”,“Status”,dID) return ((status == “1”) == allow) In the end, It involves a very short piece of LUA code - but don't worry, all the information is here. Full Device ID List.

Vera account suspended for a 1000 years Vera about 16 hours from now little about programming languages generally, but enough to ask: Has LUUP been 

errors. 08 12/28/19 14:13:25.268 JobHandler_LuaUPnP::HandleActionRequest argument SceneNum=45 <0x74447520> 08 12/28/19 14:13:25.268 JobHandler_LuaUPnP::HandleActionRequest argument rand=0.09390159472028337 <0x74447520> 08 12/28/19 14:13:25.268 Examples are given for reading a device variable using luup.variable_get(…) and for initiating an action with luup.call_action(…). It is also possible to directly set device variables but, in many cases, this will have little or no apparent effect on the device. and this: luup.variable_set(“urn:micasaverde-com:serviceId:ZWaveDevice1”,“VariablesSet”,“3,1d,2”,nn) The device/Vera accepts the code, but the device does not change the parameter.

Vera luup code examples

I have tried multiple codes i have found all over this forum. They ethier fail to run or run but no data is received. i have editted out quote and replaced . i can not get any examples of the os.execute()to work. here’s another script i have messed with to no avail.

Vera luup code examples

luup.call_action ("urn:upnp-org:serviceId:Dimming1","SetLoadLevelTarget", { newLoadlevelTarget="99" },19) end. and it works if I manually tell it to GO. For example, looking at the code for the LUUP Weather plugin, we can see where the "serviceID" for Current Conditions is urn:micasaverde-com:serviceId:Weather1 (taken from the XML file): -- Store the current Condition (eg. "rain") luup.variable_set ( "urn:upnp-micasaverde-com:serviceId:Weather1" , "ConditionGroup" , condition, PARENT_DEVICE ) [code]local vcvar1 = luup.variable_get(“urn:upnp-org:serviceId:VContainer1”, “Variable1”, dID) luup.variable_set(“urn:upnp-org:serviceId:VContainer1”, “Variable1”,newvalue, dID) luup.variable_set(“urn:upnp-org:serviceId:VContainer1”, “Variable5”,“newtext”, dID)[/code] DayTime plugin Controlling a device example.

The Lua code can use "if-then" conditions to perform custom actions, even abort the execution of the scene. For example, you want to turn on a heater in the basement at 8:00pm every night only if the outside temperature is below 40 degrees, and turn on a second heater if the outside temperature is below 20 degrees.
Tryckfallsdiagram kanaler

Vera luup code examples

Om du vill börja att skriva Luup kod till din Vera så finns det en introsida här som ger dig mer information om hur du kommer igång. På denna sida kan du läsa mer om Luup funktionerna. Vill du se exempel på hur du skapar en enhet så finns denna sida tillgänglig, som går genom Somfy plugin som pratar RS232 och Luup koden runt om detta. Hello.

and this: luup.variable_set(“urn:micasaverde-com:serviceId:ZWaveDevice1”,“VariablesSet”,“3,1d,2”,nn) The device/Vera accepts the code, but the device does not change the parameter.
Salting eggplant

seb foretagsobligation
sd ideologi
vårdcentralen orminge centrum
aparador sid
manilla gymnasium stockholm

I have tried multiple codes i have found all over this forum. They ethier fail to run or run but no data is received. i have editted out quote and replaced . i can not get any examples of the os.execute()to work. here’s another script i have messed with to no avail.

The Lua code can use "if-then" conditions to perform custom actions, even abort the execution of the scene. For example, you want to turn on a heater in the basement at 8:00pm every night only if the outside temperature is below 40 degrees, and turn on a second heater if the outside temperature is below 20 degrees. Now I can write the conditional: local lul_tmp = luup.variable_get ("urn:upnp-org:serviceId:SwitchPower1","Status",20) if ( lul_tmp=="1" ) then. luup.call_action ("urn:upnp-org:serviceId:Dimming1","SetLoadLevelTarget", { newLoadlevelTarget="99" },19) end. and it works if I manually tell it to GO. For example, looking at the code for the LUUP Weather plugin, we can see where the "serviceID" for Current Conditions is urn:micasaverde-com:serviceId:Weather1 (taken from the XML file): -- Store the current Condition (eg.

Vera is built on Luup. See: Vera Luup Releases nl for info on the latest Luup firmware release for Vera with a summary of known issues and current development, and instructions on upgrading your firmware to the latest version of Luup. Vera allows users to customize their smarthome solution, add support for new devices, and control Vera from

The GroupDevices has been kept for compatibility reasons with old versions but the use of GroupZones is now recommended. If you like Vera, but hate how it crashes often and would like it to run faster and more reliably on a different hardware platform, then this is the environment for you! Release 3 is a quite extensive (but not complete) implementation of Luup, and includes a set of features which are generally sufficient to run a number of standard plugins. Following is the example code that I use for logging opening of my home's front The custom function is defined in the Lua startup file that Vera provides, and  Dec 11, 2017 To let the wall controller communicate in scene mode with the Vera, we Now its time for the LUUP code, which need to be applied within this scene also: only an example of the configuration, but more options are po Scenes are written in Vera's Luup (Lua-UPnP) language and can be I provide basic working code examples but you must modify them for your application. Here is an example of the lua I use when sending V_VAR1 to a add it as an action in a scene under "Also, execute the following Luup code:".

The GroupDevices has been kept for compatibility reasons with old versions but the use of GroupZones is now recommended. If you like Vera, but hate how it crashes often and would like it to run faster and more reliably on a different hardware platform, then this is the environment for you! Release 3 is a quite extensive (but not complete) implementation of Luup, and includes a set of features which are generally sufficient to run a number of standard plugins. Following is the example code that I use for logging opening of my home's front The custom function is defined in the Lua startup file that Vera provides, and  Dec 11, 2017 To let the wall controller communicate in scene mode with the Vera, we Now its time for the LUUP code, which need to be applied within this scene also: only an example of the configuration, but more options are po Scenes are written in Vera's Luup (Lua-UPnP) language and can be I provide basic working code examples but you must modify them for your application. Here is an example of the lua I use when sending V_VAR1 to a add it as an action in a scene under "Also, execute the following Luup code:". 4.3.1 – if then else.